Accessories for GFS-3000
Interface 3010-I/Box
Interface establishing a connection between the socket COMP and the USB-port of a PC. Suitable for direct operation of the Standard Measuring Heads 3010-S, the Dual-PAM Gas-Exchange Cuvette 3010-DUAL, the Gas-Exchange Chamber 3010-GWK1, or any Control Unit by an external PC.
![](assets/images/9/acc-gfs-3000-interface-3010-ibox-58b31aff.jpg)
Accessories for the Standard Measuring Head 3010-S
Leaf Area Adapters
- 3010-4.5x2.22 10 cm2 (4.5 x 2.22 cm)
- 3010-0.5x2.5 1.25 cm2 (0.5 x 2.5 cm)
- 3010-1x4 4 cm2 (1 x 4 cm)
- 3010-2.19x1.14 2.5 cm2 (2.19 x 1.14 cm)
- 3010-2.19x1.14C 2.5 cm2 located at the corner (2.19 x 1.14 cm)
- 3010-2.19x1.14L 2.5 cm2 lengthwise (2.19 x 1.14 cm)
- 3010-2.58x1.93 5 cm2 (2.58 x 1.93 cm)
- 3010-2x4 8 cm2 (2 x 4 cm)
- 3010-R3 3 cm2 round (Ø 1,95 cm)
![](assets/images/1/adapters_1xl-0f1994e6.jpg)
Various Cuvettes
- Lichens/Mosses Cuvette 3010-V32
- Lichens/Mosses Cuvette 3010-V40
- Conifers Cuvette 3010-V80
- Arabidopsis Chamber 3010-A
![](assets/images/d/acc-gfs-3000-lichens-mosses-cuvette-3031-v32-467f15d0.jpg)
![](assets/images/7/acc-gfs-3000-lichens-mosses-cuvette-3031-v40-a5e3e7f2.jpg)
![](assets/images/5/acc-gfs-3000-conifers-cuvette-3010-v80-07bf0410.jpg)
![](assets/images/7/acc-gfs-3000-arabidopsis-chamber-3010-a-fb4672ec.jpg)
Compact Tripod ST-1010
Stable tripod for mounting the Standard Measuring Head 3010-S
![](assets/images/d/st_1010_1xl-7984423d.jpg)
Accessories for Fluorescence Experiments
Fiberoptics PAM-Fluorometer 3050-F
The long lasting experience in PAM fluorometry of Heinz Walz GmbH is embedded in the PAM fluorometers 3057-FL and 3050-F.
To analyze fluorescence in ambient light, the Fiberoptics PAM-Fluorometer 3050-F can be attached to the Standard Measuring Head 3010-S. It employs a blue LED for measuring light and the saturating light pulses, and also features far-red illumination for Fo’ determination.
The Fiberoptics PAM-Fluorometer 3050-F can be directly operated with the GFS-3000 in the field.
![](assets/images/7/3050-f_1xl-4ec47034.jpg)
![](assets/images/6/3050-f_2xl-09475949.jpg)
Dark Leaf Clips 3010-DLC
For the determination of the maximum fluorescence signal (Fm), the leaf needs to be dark acclimated. The light-weight dark leaf clips, with positioning aid and sliding shutters, made from sun reflecting material, fit to the measuring area of the Standard Measuring Head 3010-S.
![](assets/images/c/dark_leaf_clip_2xl-983c3a36.jpg)
![](assets/images/9/dark_leaf_clip_3xl-fa7e5874.jpg)
Oxygen Sensor 3085-O2
In chlorophyll-fluorescence research, experiments are sometimes performed at decreased oxygen concentrations to avoid photorespiration. The optical oxygen sensor 3085-O2 plugs directly into the gas pathway of the GFS-3000 to record actual oxygen concentrations; communication via USB
![](assets/images/2/GFS-3000_acc_sensor_1_xl-715978ee.jpg)
![](assets/images/b/GFS-3000_acc_sensor_2_xl-ffc75f21.jpg)
Leaf Area Adapter 3010-F-2010
Adapter for attachment of the Special Fiberoptics 2010-F (see PAM-2500) to the GFS-3000. Leaf area: 8 cm2
![](assets/images/3/3010-f-2010_1xl-13e091eb.jpg)
Miniature Fiberoptics MINI-PAM 3010-F-MINI
Fiberoptics for connection of the MINI-PAM to the GFS-3000. Active diameter 1.5 mm, length 1.5 m, including adapter for the attachment to the Standard Measuring Head 3010-S.
![](assets/images/1/3010-f-mini_1xl-285e18a2.jpg)
Accessories for System Combinations
Adapter IMAG-MIN/GFS
Adapter plate necessary to couple the IMAGING-PAM M-Series MINI version with the Standard Measuring Head 3010-S.
![](assets/images/4/imag-min_gfs_1xl-a0ae34a3.jpg)
Adapter IMAG‐MAX/GWK1
Adapter to couple the IMAGING-PAM M-Series MAXI version with the Gas-Exchange Chamber 3010-GWK1.
![](assets/images/d/_DSC2617-pol_xl-e3b67afc.jpg)
DUAL‐PAM Gas-Exchange Cuvette 3010-DUAL
Gas exchange cuvette designed for simultaneous measurements of gas exchange and PSI /PS II photochemistry.
![](assets/images/d/gfs_dual_1xl-56673e10.jpg)
Accessories concerning power
eSMART-Battery 98 Wh
2 pcs eSMART Batteries should be inserted into the Control Unit 3200-C, 4 pcs are included within the system package GFS-3000 and GFS-3000FL. Operating time with two batteries: 3 - 4.5 hours. Power: 14.4 V/ 6.8 Ah each.
eSMART Battery Charger
for simultaneous charging of four batteries, included in the system package GFS-3000 and GFS-3000FL (input: 100-240 V AC, 50/60 Hz).
DC-DC Converter 3020-DC (for Control Unit 3000-C)
For supplying power to the Control Unit model 3000-C from an external DC (12-24V, e.g. car battery), which has no special connectors. Input voltage 9-32 V, output current max. 6 A with under voltage and over temperature protection.
Battery Cable 3100-C/BC (for Control Unit 3100-C)
For supplying voltage to the Control Unit model 3100-C from an external DC (12-24V, e.g. car battery), which has no special connectors.
Battery Adapter 3200-C/BC (for Control Unit 3200-C)
For supplying voltage to the Control Unit model 3200-C from an external DC (12-24 V, e.g. car battery), which has no special connectors.
Additional accessoires
Outdoor-Set 3000-C/OS
Consisting of sun protection shield for control unit, buffer vessel 10 l, with holding net, fiber glass rod 2.5 m and tubing.