Accessories for GFS-3000

Interface 3010-I/Box

Interface establishing a connection between the socket COMP and the USB-port of a PC. Suitable for direct operation of the Standard Measuring Heads 3010-S, the Dual-PAM Gas-Exchange Cuvette 3010-DUAL, the Gas-Exchange Chamber 3010-GWK1, or any Control Unit by an external PC.

Accessories for the Standard Measuring Head 3010-S

Leaf Area Adapters

  • 3010-4.5x2.22 10 cm2 (4.5 x 2.22 cm)
  • 3010-0.5x2.5 1.25 cm2 (0.5 x 2.5 cm)
  • 3010-1x4 4 cm2 (1 x 4 cm)
  • 3010-2.19x1.14 2.5 cm2 (2.19 x 1.14 cm)
  • 3010-2.19x1.14C 2.5 cm2 located at the corner (2.19 x 1.14 cm)
  • 3010-2.19x1.14L 2.5 cm2 lengthwise (2.19 x 1.14 cm)
  • 3010-2.58x1.93 5 cm2 (2.58 x 1.93 cm)
  • 3010-2x4 8 cm2 (2 x 4 cm)
  • 3010-R3 3 cm2 round (Ø 1,95 cm)

Various Cuvettes

  • Lichens/Mosses Cuvette 3010-V32
  • Lichens/Mosses Cuvette 3010-V40
  • Conifers Cuvette 3010-V80
  • Arabidopsis Chamber 3010-A
Lichens/Mosses Cuvette 3010-V32
Lichens/Mosses Cuvette 3010-V40
Conifers Cuvette 3010-V80
Arabidopsis Chamber 3010-A

Compact Tripod ST-1010

Stable tripod for mounting the Standard Measuring Head 3010-S

Accessories for Fluorescence Experiments

Fiberoptics PAM-Fluorometer 3050-F

The long lasting experience in PAM fluorometry of Heinz Walz GmbH is embedded in the PAM fluorometers 3057-FL and 3050-F.

To analyze fluorescence in ambient light, the Fiberoptics PAM-Fluorometer 3050-F can be attached to the Standard Measuring Head 3010-S. It employs a blue LED for measuring light and the saturating light pulses, and also features far-red illumination for Fo’ determination.

The Fiberoptics PAM-Fluorometer 3050-F can be directly operated with the GFS-3000 in the field.

Dark Leaf Clips 3010-DLC

For the determination of the maximum fluorescence signal (Fm), the leaf needs to be dark acclimated. The light-weight dark leaf clips, with positioning aid and sliding shutters, made from sun reflecting material, fit to the measuring area of the Standard Measuring Head 3010-S.

Oxygen Sensor 3085-O2

In chlorophyll-fluorescence research, experiments are sometimes performed at decreased oxygen concentrations to avoid photorespiration. The optical oxygen sensor 3085-O2 plugs directly into the gas pathway of the GFS-3000 to record actual oxygen concentrations; communication via USB

Leaf Area Adapter 3010-F-2010

Adapter for attachment of the Special Fiberoptics 2010-F (see PAM-2500) to the GFS-3000. Leaf area: 8 cm2

Miniature Fiberoptics MINI-PAM 3010-F-MINI

Fiberoptics for connection of the MINI-PAM to the GFS-3000. Active diameter 1.5 mm, length 1.5 m, including adapter for the attachment to the Standard Measuring Head 3010-S.

Accessories for System Combinations

Adapter IMAG-MIN/GFS

Adapter plate necessary to couple the IMAGING-PAM M-Series MINI version with the Standard Measuring Head 3010-S.

Adapter IMAG‐MAX/GWK1

Adapter to couple the IMAGING-PAM M-Series MAXI version with the Gas-Exchange Chamber 3010-GWK1.

DUAL‐PAM Gas-Exchange Cuvette 3010-DUAL

Gas exchange cuvette designed for simultaneous measurements of gas exchange and PSI /PS II photochemistry.

Accessories concerning power

eSMART-Battery 98 Wh

2 pcs eSMART Batteries should be inserted into the Control Unit 3200-C, 4 pcs are included within the system package GFS-3000 and GFS-3000FL. Operating time with two batteries: 3 - 4.5 hours. Power: 14.4 V/ 6.8 Ah each.

eSMART Battery Charger

for simultaneous charging of four batteries, included in the system package GFS-3000 and GFS-3000FL (input: 100-240 V AC, 50/60 Hz).

DC-DC Converter 3020-DC (for Control Unit 3000-C)

For supplying power to the Control Unit model 3000-C from an external DC (12-24V, e.g. car battery), which has no special connectors. Input voltage 9-32 V, output current max. 6 A with under voltage and over temperature protection.

Battery Cable 3100-C/BC (for Control Unit 3100-C)

For supplying voltage to the Control Unit model 3100-C from an external DC (12-24V, e.g. car battery), which has no special connectors.

Battery Adapter 3200-C/BC (for Control Unit 3200-C)

For supplying voltage to the Control Unit model 3200-C from an external DC (12-24 V, e.g. car battery), which has no special connectors.

Additional accessoires

Outdoor-Set 3000-C/OS

Consisting of sun protection shield for control unit, buffer vessel 10 l, with holding net, fiber glass rod 2.5 m and tubing.