Accessories

GFS-3000

Interface Box

Interface Box establishing a connection between the socket COMP and the USB-port of a PC. Suitable for direct operation of the Standard Measuring Heads 3010-S, the Dual-PAM Gas-Exchange Cuvette 3010-DUAL, the Gas-Exchange Chamber 3010-GWK1 or the Control Units 3000-C or 3100-C by an external PC



Accessories for the Standard Measuring Head 3010-S

Leaf Area Adapters

3010-4.5x2.22 Leaf Area Adapter 10 cm2 (4.5 x 2.22 cm)
3010-0.5x2.5 Leaf Area Adapter 1.25 cm2 (0.5 x 2.5 cm)
3010-1x4 Leaf Area Adapter 4 cm2 (1 x 4 cm)
3010-2.19x1.14 Leaf Area Adapter 2.5 cm2 (2.19 x 1.14 cm)
3010-2.19x1.14C Leaf Area Adapter 2.5 cm2 located at the corner (2.19 x 1.14 cm)
3010-2.58x1.93 Leaf Area Adapter 5 cm2 (2.58 x 1.93 cm)
3010-2x4 Leaf Area Adapter 8 cm2 (2 x 4 cm)
3010-R3 round Leaf Area Adapter 3 cm2 (Ø 1,95 cm)

Various Cuvettes

Lichens/Mosses Cuvette 3010-V32
Lichens/Mosses Cuvette 3010-V40
Conifers Cuvette 3010-V80
Arabidopsis Chamber 3010-A


Compact Tripod ST-1010

Stable tripod for mounting the Standard Measuring Head 3010-S



Accessories for Fluorescence Components

Dark Leaf Clips 3010-DLC

For the determination of the maximum fluorescence signal (Fm), the leaf needs to be dark acclimated. The light-weight dark leaf clips, with positioning aid and sliding shutters, made from sun reflecting material, fit to the measuring area of the Standard Measuring Head 3010-S.

Oxygen Sensor 3080-O2

In chlorophyll-fluorescence research, experiments are sometimes performed at decreased oxygen concentrations to avoid photorespiration. The Oxygen Sensor 3080-O2 can be used as stand-alone system or it can be directly connected to the Central Unit for the recording of the actual oxygen concentration. It comprises a maintenance free lead-oxygen battery and is insensitive to CO2. The resolution at the GFS-3000 is 0.03% O2.


Leaf Area Adapter 3010-F-2010

Adapter for attachment of the Special Fiberoptics 2010-F (see PAM-2500) to the GFS-3000. Leaf area: 8 cm2

Miniature Fiberoptics MINI-PAM
3010-F-MINI

Fiberoptics for connection of the MINI-PAM to the GFS-3000. Active diameter 1.5 mm, length 1.5 m, including adapter for the attachment to the Standard Measuring Head 3010-S.



Accessories for System Combinations

Adapter IMAG-MIN/GFS

Adapter plate necessary to couple the IMAGING-PAM M-Series MINI version with the Standard Measuring Head 3010-S.

Adapter IMAG‐MAX/GWK1

Adapter to couple the IMAGING-PAM M-Series MAXI version with the Gas-Exchange Chamber 3010-GWK1.


DUAL‐PAM Gas-Exchange Cuvette
3010-DUAL

Gas exchange cuvette designed for simultaneous measurements of gas exchange and PSI /PS II photochemistry.


Accessories concerning power

LiFePO4 Battery 3035-A

Power supply for the GFS-3000 in the field, included in the system package GFS-3000 and GFS-3000FL. Operating time: 3 - 4.5 hours. Power: 12.8 V / 15 Ah (2x 7.5 Ah).

DC-DC Converter 3020-DC (for Control
Unit 3000-C)

For supplying power to the Control Unit model 3000-C from an external DC (12-24V, e.g. car battery), which has no special connectors. Input voltage 9-32 V, output current max. 6 A with under voltage and over temperature protection.


Battery Charger LC-03

For simultaneous recharging of 2 LiFePO4 Batteries 3035-A, included in the system package GFS-3000 and GFS-3000FL

Battery Cable 3100-C/BC (for Control
Unit 3100-C)

For supplying voltage to the Control Unit model 3100-C from an external DC (12-24V, e.g. car battery), which has no special connectors.



Additional accessoires

Outdoor-Set 3000-C/OS

Consisting of sun protection shield for control unit, buffer vessel 10 l, with holding net, fiber glass antenna 2.5 m and tubing.

Control Unit 3000-C with Insert for Drier

If the system shall be operated in extremely humid environments, an insert for silica gel can be built into the housing of the Control Unit 3000-C.